Sheds, carports and garages in Redland — do you need approval?
Redland City Council's planning scheme — the Redland City Plan 2018 — decides whether a shed, carport or garage needs a development application, and the answer depends on the zone your property is in. Below is what its table of assessment says for each zone; or check your own address.
In a low density residential zone
No planning approval needed. A domestic shed, carport or garage is accepted development needing no planning development application, but if it is associated with a dwelling in precincts LDR1-LDR5 or a dual occupancy in LDR5 it must meet the zone code (a building approval is still required).
I don't know my zone — choose my council instead
The zone is on your rates notice, or a Landbrief site report will find it for you.
Zone by zone
Building work (a domestic outbuilding). Residential zones first.
| Zone | What the table says | Conditions | What you'll need |
|---|---|---|---|
| Low density residential zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is accepted development needing no planning development application, but if it is associated with a dwelling in precincts LDR1-LDR5 or a dual occupancy in LDR5 it must meet the zone code (a building approval is still required). | Building approval (private certifier)Assessed against: Low density residential zone code |
| Low-medium density residential zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is accepted development in this zone and needs no planning development application (a building approval is still required). | Building approval (private certifier) |
| Medium density residential zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is accepted development in this zone and needs no planning development application (a building approval is still required). | Building approval (private certifier) |
| Character residential zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is accepted development in this zone and needs no planning development application (a building approval is still required). | Building approval (private certifier) |
| Emerging community zone | No planning approval needed Table 5.6.1 | A domestic shed or carport is accepted building work here under the planning scheme, though a building approval under the Building Act is still required. | Building approval (private certifier) |
| Tourist accommodation zone | No planning approval needed Table 5.6.1 | A shed or carport for a house is accepted unless an overlay applies, but you still need a building approval. | Building approval (private certifier) |
| Community facilities zone | No planning approval needed Table 5.6.1 | A domestic shed or carport is accepted building work here under the planning scheme, though a building approval under the Building Act is still required. | Building approval (private certifier) |
| Conservation zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted development needing no planning application in this zone (though a building approval is still required), unless an overlay applies. | Building approval (private certifier) |
| District centre zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted unless an overlay applies, but you still need a building approval. | Building approval (private certifier) |
| Environmental management zone | No planning approval needed Table 5.6.1 | A shed or carport for a house is accepted development needing no planning application in this zone (though a building approval is still required), unless an overlay applies. | Building approval (private certifier) |
| Local centre zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is any other building work not listed, so it is accepted and needs no planning development application (though a building approval may still be required). | Building approval (private certifier) |
| Low impact industry zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted development needing no planning application in this zone (though a building approval is still required), unless an overlay applies. | Building approval (private certifier) |
| Major centre zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted unless an overlay applies, but you still need a building approval. | Building approval (private certifier) |
| Medium impact industry zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted development needing no planning application in this zone (though a building approval is still required), unless an overlay applies. | Building approval (private certifier) |
| Mixed use zone | No planning approval needed Table 5.6.1 | A domestic shed or carport is accepted building work here under the planning scheme, though a building approval under the Building Act is still required. | Building approval (private certifier) |
| Neighbourhood centre zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is any other building work not listed, so it is accepted and needs no planning development application (though a building approval may still be required). | Building approval (private certifier) |
| Principal centre zone | No planning approval needed Table 5.6.1 | A shed or carport is accepted unless an overlay applies, but you still need a building approval. | Building approval (private certifier) |
| Recreation and open space zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is any other building work not listed, so it is accepted and needs no planning development application (though a building approval may still be required). | Building approval (private certifier) |
| Rural zone | No planning approval needed Table 5.6.1 | A shed, carport or garage on a rural property is accepted development and does not need a planning development application, though a building approval may still be required and overlays can add requirements. | Building approval (private certifier) |
| Specialised centre zone | No planning approval needed Table 5.6.1 | A domestic shed, carport or garage is any other building work not listed, so it is accepted and needs no planning development application (though a building approval may still be required). | Building approval (private certifier) |
| Waterfront and marine industry zone | No planning approval needed Table 5.6.1 | A domestic shed or carport is accepted building work here under the planning scheme, though a building approval under the Building Act is still required. | Building approval (private certifier) |
Overlays that change the answer
- Coastal protection (erosion prone areas) overlay. On land mapped as erosion prone, material change of use or building work for a dwelling house (including a secondary dwelling), dual occupancy or community residence becomes code assessable and must be assessed against the Coastal protection (erosion prone areas) overlay code. (5.9.1 Coastal protection (erosion prone areas) overlay)
- Flood and storm tide hazard overlay. On land mapped as drainage constrained, material change of use or building work for a dwelling house (including a secondary dwelling) or community residence becomes code assessable and must be assessed against the Flood and storm tide hazard overlay code (may particularly affect Character residential and Environmental management zones on the Southern Moreton Bay Islands). (5.9.1 Flood and storm tide hazard overlay)
- Heritage overlay. Building work involving interior/exterior alterations, extensions, or erecting a new or separate building on a local heritage place becomes code assessable against the Heritage overlay code. (5.9.1 Heritage overlay)
Worth knowing in Redland
The tables of assessment do not state numeric minimum lot sizes for reconfiguring a lot; the numeric minimums live in the Reconfiguring a lot code and individual zone codes (not reproduced here). Reconfiguring a lot is impact assessable in the Conservation, Environmental management, Character residential, Tourist accommodation and Rural zones, and in the Emerging community zone where any lot under 10ha is created; it is otherwise code assessable. Building work for a dwelling house (shed, pool, fence, extension, demolition) is generally accepted development under the planning scheme unless an overlay applies (see overlay_triggers) — but a building approval under the Building Act 1975 is still required, and dwelling-house building work in the Low density residential zone precincts LDR1–LDR5 (and dual occupancy/associated building work in LDR5) is accepted subject to requirements against the zone code. Secondary dwellings (granny flats) are treated as part of a 'dwelling house' under the QPP; a dwelling house containing a secondary dwelling still counts as one dwelling for assessment triggers in rural/emerging/environmental management/conservation zones. Where premises are in more than one zone or overlay, the highest category applies. The Transport noise corridor overlay is for information only (building work assessed under QDC Part 4.4). State Vegetation Management Act and Planning Regulation clearing exemptions operate separately from this scheme. There are no local plans in this scheme. Precinct variations (LDR1–5, MDR1–9, CF1–9) can change categories within a zone and should be checked against the relevant zone map.
What Redland City Council publishes
These come from the council's own website and planning scheme, read on 17 November 2026. Each one links to the page it came from. Councils change their rules and fees, so open the source before you rely on a figure.
- Queensland Development Code applies unless City Plan sets an alternative
- Redland applies the Queensland Development Code design, setback and siting requirements to houses and associated Class 10 buildings (garages, carports, sheds), except where the City Plan identifies an alternative provision, in which case City Plan overrides the Queensland Development Code. (Applies to: Detached dwelling houses and associated Class 10 buildings/structures.) Queensland Development Code (Redland City Council web page)
- Sheds are "domestic outbuildings"; planning approval
- Sheds are domestic outbuildings under the Redland City Plan. Where there is an existing dwelling house on the lot, a domestic outbuilding is generally accepted development and does not require planning approval, unless an overlay elevates the level of assessment. (Applies to: Lots with an existing dwelling house.) Sheds (Redland City Council web page)
- Setbacks incl. outbuildings: park residential (LDR2)
- In precinct LDR2 park residential, dwelling houses (including outbuildings) are set back 10 m from a road frontage and 10 m from a side or rear boundary. This is an alternative provision to the Queensland Development Code. (Applies to: Low density residential zone, precinct LDR2 park residential.) Redland City Plan 2018, Version 14, Part 6 Zones, 6.2.1 Low density residential zone code, Table 6.2.1.3.1 AO4.1
- Site cover: LDR1, LDR2 and LDR3
- For dwelling houses in precincts LDR1 large lot and LDR2 park residential (AO6.1), and in LDR3 Point Lookout residential (AO11.1), site cover does not exceed 30% of site area. (Applies to: Low density residential zone, precincts LDR1, LDR2 and LDR3.) Redland City Plan 2018, Version 14, Part 6 Zones, 6.2.1 Low density residential zone code, Table 6.2.1.3.1 AO6.1 and AO11.1
- Canal and lake setback incl. outbuildings (LDR5)
- In precinct LDR5 canal and lakeside estates, development including domestic outbuildings and other roofed structures (excluding in-ground swimming pools) is set back a minimum of 9 m from the property boundary adjoining a canal or lake. (Applies to: Low density residential zone, precinct LDR5 canal and lakeside estates.) Redland City Plan 2018, Version 14, Part 6 Zones, 6.2.1 Low density residential zone code, Table 6.2.1.3.1 AO9.1
- Detached building size: Point Lookout (LDR3)
- In precinct LDR3 Point Lookout residential, any single detached building component does not exceed 150 m² when not more than 4.5 m high, or 140 m² when over 4.5 m high. (Applies to: Low density residential zone, precinct LDR3 Point Lookout residential.) Redland City Plan 2018, Version 14, Part 6 Zones, 6.2.1 Low density residential zone code, Table 6.2.1.3.1 AO12.1
- Application when siting rules are not met
- If building work cannot adopt one or more acceptable solutions in the Queensland Development Code (or the City Plan where it overrides), approval from Council as a referral (concurrence) agency is needed, lodged as a concurrence agency referral application. (Applies to: Dwelling houses and associated Class 10 buildings.) Queensland Development Code (Redland City Council web page)
- Concurrence agency referral fee
- The 2026-2027 fee for a concurrence agency referral for building work under Schedule 9 of the Planning Regulation 2017 is $825.00 per application. (Applies to: 2026-2027 financial year.) Redland City Council 2026-2027 Register of Fees (fee code CONRE1.0)
The statewide rules
These are the statewide figures. A council's planning scheme can set its own, and an overlay can add more, so check your council and your address before you rely on them.
- Shed with no building approval
- A shed or similar structure with a plan area of no more than 10 m² (roof overhangs count), no higher than 2.4 m, with a mean height of no more than 2.1 m and no side longer than 5 m. It must still meet the boundary setbacks and the planning scheme.
- Cyclone areas
- That exemption doesn't apply in Wind Region C, the tropical cyclone area that takes in the coast of central and north Queensland. There, a shed of any size needs a building approval.
- Carports and garages
- A carport or garage is almost always larger than 10 m², so it needs a building approval from a private certifier or the council.
- Side and rear boundaries
- 1.5 m for a structure up to 4.5 m high, and 2 m for the part between 4.5 m and 7.5 m high.
- Building on or near the side or rear boundary
- A shed, carport or garage can sit closer than 1.5 m, including on the boundary, when it is no higher than 4.5 m, the buildings within that strip total no more than 9 m along the boundary, and it is at least 1.5 m from a habitable-room window next door. Other conditions apply.
- Street frontage
- 6 m from the road boundary on a lot of 450 m² or more, and 3 to 4 m on a smaller lot, depending on the street. An open carport can go inside that setback only when no other spot on the lot can comply.
- Site cover
- Roofed buildings, the house included, can cover no more than 50% of the lot.
- Fire separation
- A structure within 900 mm of a side or rear boundary may need fire-rated construction under the National Construction Code.
- The boundary figures come from the Queensland Development Code, parts MP 1.1 (lots under 450 m²) and MP 1.2 (lots of 450 m² or more).
- From 1 September 2026 the Queensland Housing Code replaces those parts, but only in a council area whose planning scheme has been amended to adopt it. The transition runs to 1 September 2029. Until a council adopts it, MP 1.1 and MP 1.2 still apply there.
- A design that doesn't meet the figures isn't refused outright: the certifier refers it to the council, which assesses the siting against the code's performance criteria.
What else you'll need
- Building approval (private certifier)
More about Redland
- What can you build in Redland? Council overview and development applications
- Every Queensland zone explained, with what each council allows and the planning overlays that change the answer
- What Redland City Council charges for a development application, compared with other councils
- A Landbrief site report for your Redland address — every planning layer that applies to the lot
- Development applications in Cleveland
- Development applications in Birkdale
- Development applications in Redland Bay
- Development applications in Capalaba
- Development applications in Wellington Point
- Development applications in Alexandra Hills
- Development applications in Victoria Point
- Development applications in Thornlands
Other projects in Redland
Granny flatDual occupancySubdivideExtensionPoolFence or wallHome businessTownhousesShop, café or officeClear treesDemolish
The statewide position on this project: Shed or carport in Queensland.
Read from the Redland City Plan 2018 tables of assessment. General information, not advice. The council's planning scheme and the Planning Act 2016 decide — confirm with the council or a town planner before you build.