landbrief.

Running a business from home in Townsville — do you need approval?

Townsville City Council's planning scheme — the Townsville City Plan — decides whether a home business needs a development application, and the answer depends on the zone your property is in. Below is what its table of assessment says for each zone; or check your own address.

In a low density residential zone

Accepted if you meet the requirements. A home business needs no development application if it uses no more than 60 m² inside your existing house or shed and meets the zone code requirements; a bigger business or one in a new building needs an impact assessable application.

I don't know my zone — choose my council instead

The zone is on your rates notice, or a Landbrief site report will find it for you.

Zone by zone

Home-based business. Residential zones first.

ZoneWhat the table saysConditionsWhat you'll need
Low density residential zone Accepted if you meet the requirements Table 5.5.1 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: Low density residential zone code
Medium density residential zone Accepted if you meet the requirements Table 5.5.2 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: Medium density residential zone code
High density residential zone Accepted if you meet the requirements Table 5.5.4 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: High density residential zone code
Character residential zone Accepted if you meet the requirements Table 5.5.6 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: Character residential zone code
Rural residential zone Accepted if you meet the requirements Table 5.5.5 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: Rural residential zone code
Emerging community zone Accepted if you meet the requirements Table 5.5.22 if the gross floor area is no more than 60 m² and the business is inside an existing house or domestic outbuilding (code assessable if the zone code requirements can't be met)If not met: a development application with impact assessment (neighbours can make submissions). Nothing further under the planning schemeAssessed against: Emerging community zone code
Community facilities zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.16 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
District centre zone No planning approval needed Table 5.5.9 A home based business is accepted development in the District centre zone, so no development application is needed. Nothing further under the planning scheme
Environmental management and conservation zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.17 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
High impact industry zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.20 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
Local centre zone No planning approval needed Table 5.5.8 A home based business is accepted development in the Local centre zone, so no development application is needed. Nothing further under the planning scheme
Low impact industry zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.18 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
Major centre zone No planning approval needed Table 5.5.10 A home based business is accepted development in the Major centre zone, so no development application is needed. Nothing further under the planning scheme
Medium impact industry zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.19 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
Mixed use zone No planning approval needed Table 5.5.13 A home based business is accepted development in the Mixed use zone, so no development application is needed. Nothing further under the planning scheme
Neighbourhood centre zone No planning approval needed Table 5.5.7 A home based business is accepted development in the Neighbourhood centre zone, so no development application is needed. Nothing further under the planning scheme
Open space zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.15 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme
Principal centre zone No planning approval needed Table 5.5.11 A home based business is accepted development in the Principal centre zone, so no development application is needed. Nothing further under the planning scheme
Rural zone Accepted if you meet the requirements Table 5.5.21 A home based business needs no development application in the Rural zone if it meets the Rural zone code requirements; otherwise a code assessable application is needed. Nothing further under the planning schemeAssessed against: Rural zone code
Special purpose zone It depends — see below Table 5.5.23 in the Townsville State Development Area Nothing further under the planning schemeAssessed against: Development Scheme for the Townsville State Development Area
Specialised centre zone No planning approval needed Table 5.5.12 A home based business is accepted development in the Specialised centre zone, so no development application is needed. Nothing further under the planning scheme
Sport and recreation zone Needs a development application (impact assessment — neighbours can make submissions) Table 5.5.14 Home based business is not a listed use in this zone Nothing further under the planning schemeAssessed against: The planning scheme

Overlays that change the answer

Worth knowing in Townsville

Townsville City Plan (Version 2025/01), Part 5, converted from the council's Part 5 PDF (not an official copy). A material change of use not listed in a zone table, or not meeting the listed description, is impact assessable; reconfiguring a lot is code assessable unless Table 5.6.1 says otherwise; building work and operational work are accepted unless Tables 5.7 / 5.8 or an overlay say otherwise (section 5.3.2). Accepted development subject to requirements that doesn't meet its requirements becomes code assessable (section 5.3.3(2)). Townsville regulates building work in Table 5.7.1 only in the Character residential zone (contributing character buildings and work near the street façade — see SC6.2); elsewhere building work is regulated only through overlays (heritage, flood, coastal). A building approval under the Building Act is always still needed. Granny flats: only the Low density and Rural residential zones split out a 'secondary dwelling' (accepted subject to requirements); the Rural and Emerging community zones cap a lot at two dwellings. Dual occupancy is accepted in the Low (outside the Stables precinct), Medium and High density and Character residential zones. Schedule 6 of the Planning Regulation 2017 overrides the scheme — e.g. a dwelling house in a residential zone (other than Medium or High density) can't be made assessable unless a relevant overlay applies; the Major infrastructure and hazardous facilities overlay isn't a relevant overlay, so its dwelling-house triggers don't apply in the Low density or Character residential zones. Many centre, mixed use and medium density rows vary by precinct (e.g. Table 5.5.3 storey limits of 2–8 storeys by precinct for multiple dwellings in the Medium density residential zone; Breakwater, Thuringowa centre support, Civic and administration, James Cook University–Townsville University Hospital precincts) — check the conditions. Local plans are not used in this scheme. The Special purpose zone covers the Townsville State Development Area, where change of use, subdivision and vegetation clearing are decided by the Coordinator-General. Operational work filling or excavation within 1.5 m of a boundary deeper than 300 mm, deeper than 1 m, or 100 m³ or more is code assessable in every zone (10 m³ in the high/medium flood hazard area). Where premises are in more than one zone or overlay, the highest category applies to the affected part. The Transport noise corridor overlay is for information only. The source Part 5 extract was a PDF conversion: Table 5.5.12 (Specialised centre) splits across chunks and the Table 5.8.2 advertising-device extract is incomplete.

What else you'll need

  • Nothing beyond the planning scheme's own requirements.

More about Townsville

Other projects in Townsville

Granny flatDual occupancySubdivideShed or carportExtensionPoolFence or wallTownhousesShop, café or officeClear treesDemolish

The statewide position on this project: Home business in Queensland.