landbrief.

Sheds, carports and garages in Central Highlands — do you need approval?

Central Highlands Regional Council's planning scheme — the Central Highlands Regional Council Planning Scheme 2016 (Amendment No. 7) — decides whether a shed, carport or garage needs a development application, and the answer depends on the zone your property is in. Below is what its table of assessment says for each zone; or check your own address.

In a general residential zone

Accepted if you meet the requirements. A shed, carport or garage is accepted if it meets AO11 of the Dwelling house code; if not it becomes code assessable, and a building approval is still needed.

I don't know my zone — choose my council instead

The zone is on your rates notice, or a Landbrief site report will find it for you.

Zone by zone

Building work (a domestic outbuilding). Residential zones first.

ZoneWhat the table saysConditionsWhat you'll need
General residential zone Accepted if you meet the requirements Table 5.6.1 Class 10a buildingIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
High density residential zone Accepted if you meet the requirements Table 5.6.1 Class 10a buildingIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Rural residential zone Accepted if you meet the requirements Table 5.6.1 Class 10a buildingIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Emerging community zone Accepted if you meet the requirements Table 5.6.1 Class 10a buildingIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Township zone Accepted if you meet the requirements Table 5.6.1 minor building work; or Class 10a building meeting AO11.1 and AO11.2 of the Dwelling house codeIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Centre zone Accepted if you meet the requirements Table 5.6.1 if a Class 10a building; accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Community facilities zone Accepted if you meet the requirements Table 5.6.1 Class 10a building; otherwise accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Environmental management and conservation zone Accepted if you meet the requirements Table 5.6.1 Class 10a building; otherwise accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Industry investigation zone Accepted if you meet the requirements Table 5.6.1 minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: Dwelling house code
Industry zone Accepted if you meet the requirements Table 5.6.1 minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: Dwelling house code
Low impact industry zone Accepted if you meet the requirements Table 5.6.1 minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: Dwelling house code
Neighbourhood centre zone Accepted if you meet the requirements Table 5.6.1 if a Class 10a building; accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Principal centre zone Accepted if you meet the requirements Table 5.6.1 if a Class 10a building; accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Recreation and open space zone Accepted if you meet the requirements Table 5.6.1 Class 10a building; otherwise accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code
Rural zone No planning approval needed Table 5.6.1 Class 10a building (excluding Gemfields precincts, where accepted subject to requirements applies)If not met: accepted if you meet the requirements. Building approval (private certifier)Assessed against: AO12.1 and AO12.2 of the Dwelling house code (Gemfields precincts)
Special industry zone Accepted if you meet the requirements Table 5.6.1 minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: Dwelling house code
Specialised centre zone Accepted if you meet the requirements Table 5.6.1 if a Class 10a building; accepted if minor building workIf not met: a development application with code assessment. Building approval (private certifier)Assessed against: AO11.1 and AO11.2 of the Dwelling house code

Overlays that change the answer

  • Flood hazard overlay. Within a flood risk category the category of development can change. A dwelling house (incl. secondary dwelling) material change of use / building work in the Balance Flood Risk Category is accepted only where the habitable floor is at least 300mm above natural ground level and no filling is involved; in the Low Risk Flood Category dwelling house / dwelling unit / dual occupancy / home based business is accepted only where habitable floor is at least Defined Flood Event + 300mm and no filling. Building work in Medium/High/Very High flood risk categories becomes code assessable. Reconfiguring a lot in any flood risk category is code assessable. Multiple dwelling (townhouses) in Medium/High/Very High flood risk categories becomes impact assessable. Otherwise code assessable unless accepted conditions met. (Table 5.8.1 Overlays — Flood hazard overlay)
  • Bushfire hazard overlay. Where within a medium, high, very high or potential impact buffer bushfire hazard area, building work involving a dwelling house, a listed material change of use (accommodation, business, industry, community, recreation activity groups) and reconfiguring a lot must be assessed against the Bushfire hazard overlay code (no change to category but overlay code applies as accepted requirements). (Table 5.8.1 Overlays — Bushfire hazard overlay)
  • Heritage overlay. Building work not associated with a material change of use that involves alteration, demolition, relocation or removal of a local heritage place becomes code assessable (against Heritage overlay code) where it would otherwise be accepted subject to requirements. A material change of use involving a local heritage place resulting in such building work also becomes code assessable. Applies to premises that are, or adjoin, a local heritage place. (Table 5.8.1 Overlays — Heritage overlay)

Worth knowing in Central Highlands

Minimum lot sizes, frontages and rectangular developable areas for each zone are set in Table 8.4.3.3.2 (Minimum lot size and dimensions), which was not reproduced in the supplied material, so numeric minimums could not be captured; the Reconfiguring a lot code (section 8.4.3) and Table 8.2.2 govern subdivision of one lot into two. Under the Regulation, subdivision of one lot into two lots is always code assessable (Schedule 10). The Rural zone contains Gemfields Core, Gemfields Frame and Gemfields Balance precincts which materially change the category of assessment for many uses (e.g. dwelling unit, shop, office, food and drink outlet, community uses) — owners in those precincts should check precinct-specific rows. Building work for a dwelling house and Class 10a outbuildings is generally accepted or accepted subject to requirements across all zones (and fully accepted for Class 10a in the Rural zone outside the Gemfields precincts); a building approval under the Building Act 1975 is still required separately. Development that is accepted does not need a development application. Home-based business is accepted subject to requirements in most zones provided it is not a high impact home-based business activity. Where a use is not listed for a zone the 'all other uses / undefined use' row applies, making it impact assessable. Overlay effects apply only to the part of the premises affected, and the highest applicable category prevails where zone and overlay differ. State Vegetation Management Act clearing controls operate separately from the scheme's operational work provisions.

What Central Highlands Regional Council publishes

These come from the council's own website and planning scheme, read on 17 November 2026. Each one links to the page it came from. Councils change their rules and fees, so open the source before you rely on a figure.

Maximum shed size
A development permit application to Council is required if the shed, or all sheds combined on a property, is greater than 100 m². (Applies to: All zones except Rural zone (see separate row).) Sheds and carports (Central Highlands Regional Council web page)
Maximum shed wall height
A shed with internal walls higher than 4.5 m triggers a development permit against the planning scheme. (Applies to: All zones except Rural zone (see separate row).) Sheds and carports (Central Highlands Regional Council web page)
Rural zone sheds
Council says there are no planning scheme requirements for a class 10a shed in the Rural zone; building approval from a private certifier is still needed. (Applies to: Rural zone.) Fact Sheet: Sheds, Carports and Setbacks (uploaded July 2022)
Setbacks - council defers to Queensland Development Code
Council says shed size and height are set by the planning scheme and setbacks by the Queensland Development Code; a shed over 9 m long must be 1.5 m from side and rear boundaries. (Applies to: Class 10a structures.) Fact Sheet: Sheds, Carports and Setbacks (uploaded July 2022)
Carport or shed in the front setback
Placing a structure such as a carport within 6 m of the front of the lot requires a relaxation application to Council. (Applies to: Road boundary setback.) Fact Sheet: Sheds, Carports and Setbacks (uploaded July 2022)
Application names
Oversize or over-height sheds need a Building Works assessable against the Planning Scheme (BWAP) application; setback relaxations need a Referral Agency Application. (Applies to: Sheds and carports.) Sheds and carports (Central Highlands Regional Council web page)
Application fees 2026-27
In 2026-27 the fee for Category 1 Building Work Assessable against the Planning Scheme (Dwelling House Code) is $750.00, and for a Concurrence Referral - Boundary Relaxation (Class 1 & 10) is $638.00. (Applies to: 2026-27 financial year.) Central Highlands Regional Council 2026-27 Fees & Charges (effective 1 July 2026)

The statewide rules

These are the statewide figures. A council's planning scheme can set its own, and an overlay can add more, so check your council and your address before you rely on them.

Shed with no building approval
A shed or similar structure with a plan area of no more than 10 m² (roof overhangs count), no higher than 2.4 m, with a mean height of no more than 2.1 m and no side longer than 5 m. It must still meet the boundary setbacks and the planning scheme.
Cyclone areas
That exemption doesn't apply in Wind Region C, the tropical cyclone area that takes in the coast of central and north Queensland. There, a shed of any size needs a building approval.
Carports and garages
A carport or garage is almost always larger than 10 m², so it needs a building approval from a private certifier or the council.
Side and rear boundaries
1.5 m for a structure up to 4.5 m high, and 2 m for the part between 4.5 m and 7.5 m high.
Building on or near the side or rear boundary
A shed, carport or garage can sit closer than 1.5 m, including on the boundary, when it is no higher than 4.5 m, the buildings within that strip total no more than 9 m along the boundary, and it is at least 1.5 m from a habitable-room window next door. Other conditions apply.
Street frontage
6 m from the road boundary on a lot of 450 m² or more, and 3 to 4 m on a smaller lot, depending on the street. An open carport can go inside that setback only when no other spot on the lot can comply.
Site cover
Roofed buildings, the house included, can cover no more than 50% of the lot.
Fire separation
A structure within 900 mm of a side or rear boundary may need fire-rated construction under the National Construction Code.
  • The boundary figures come from the Queensland Development Code, parts MP 1.1 (lots under 450 m²) and MP 1.2 (lots of 450 m² or more).
  • From 1 September 2026 the Queensland Housing Code replaces those parts, but only in a council area whose planning scheme has been amended to adopt it. The transition runs to 1 September 2029. Until a council adopts it, MP 1.1 and MP 1.2 still apply there.
  • A design that doesn't meet the figures isn't refused outright: the certifier refers it to the council, which assesses the siting against the code's performance criteria.

What else you'll need

  • Building approval (private certifier)

More about Central Highlands

Other projects in Central Highlands

Granny flatDual occupancySubdivideExtensionPoolFence or wallHome businessTownhousesShop, café or officeClear treesDemolish

The statewide position on this project: Shed or carport in Queensland.

Read from the Central Highlands Regional Council Planning Scheme 2016 (Amendment No. 7) tables of assessment. General information, not advice. The council's planning scheme and the Planning Act 2016 decide — confirm with the council or a town planner before you build.